EPA-250/330/400
AC-DC
250W/330W/400W
|
|
|
 |
Model
#
|
|
+5V
|
+3.3V
|
+12V
|
-5V
|
-12V
|
Standby
5VSB
|
Input
Amp
|
EPA-250 |
Max.
Load |
25
|
16
|
10
|
1
|
1
|
2
|
115VAC
/6A
|
Min.
Load |
3
|
0.5
|
1
|
0
|
0
|
0
|
230VAC
/3.5A
|
EPA-330 |
Max.
Load |
30
|
30
|
12
|
1
|
1
|
2
|
115VAC
/6A
|
Min.
Load |
3
|
0
|
1
|
0
|
0
|
0
|
230VAC
/3.5A
|
EPA-400 |
Max.
Load |
45
|
35
|
15
|
1
|
1
|
2
|
115VAC
/7A
|
Min.
Load |
3
|
0
|
1
|
0
|
0
|
0
|
230VAC
/4A
|
Load
Reg. |
|
+/-5%
|
+/-5%
|
+/-5%
|
+/-10%
|
+/-10%
|
+/-10%
|
For
2U chassis and front loading available
|
Cross
Reg. |
|
+/-5%
|
+/-5%
|
+/-5%
|
+/-10%
|
+/-10%
|
+/-10%
|
Line
Reg. |
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-1%
|
Ripple |
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-1%
|
Noise |
|
+/-1%
|
+/-1%
|
+/-1%
|
+/-2%
|
+/-2%
|
+/-2%
|
|
- Standard PS/2 form
factor
- Auto ranging AC
input available
- Standard PC connection
wiring interface
- Special design
of 83mm height for 2U chassis
- Front loading available
- Over temperature
protection (optional)
- Over current protection
(+55V, +3.3V, +12V)
- Under voltage protection
- Meets the latest
ATX specifications of Intel
- Remote DC sense
for specified load cable drop
- UL, CUL, TUV, CE
- 2 years warranty
- MTBF >= 100,000
hours
|
Efficiency |
65%
minimum. at full load |
Holdup
Time |
20mS
at full load |
Power
Good Signal |
100
to 500 mS |
Over
Current Protection |
+5V,
+3.3V & -12V:110%~130%
+12V: 120%~150% |
Over
Voltage Protection |
+5V:
5.6V~6.9V
+3.3V: 3.7V~4.5V
+12V:13.6V~15.6V |
Over
Power Protection |
Total
output 110% minimum to 130% maximum |
Air
Flow |
39
CFM per minute |
Temperature |
30°
to 122°F (0°-50°C) |
Humidity |
Operating:
20-90% non-condensing |
Safety
Standards |
 |
RFI/EMI
Standards meet |
FCC
part 15, class B;CISPR 22 (EN550022); VCCI class 2 |
Dimensions |
W
x H x D: 5.90 x 3.38 x 5.51 inches/150 x 86 x 140 mm |
Packing |
6pcs per carton
Net weight: 27.5lb (12.5Kg)
Gross weight: 29.7lb (13.5Kg)
Cu. ft.: 1.9
|
|
|